SE702 Schmocker phase-angle control

The SE702 is a digital phase-angle control with LC display for electromagnetic vibrators or 1-phase capacitor motors with external PLC connection.

The SE702 is an easily configurable controller for mains-operated feeding systems. It is used to control electromagnetic bowl and linear feeders as well as vibratory hoppers or for switching 1-phase capacitor motors. The feeding process is monitored via a higher-level controller (PLC).

All settings are made via a backlit LC display. Parameters can be protected by access codes. Individual parameter sets can be stored and retrieved for up to ten different feeders.

In vibrator mode, the vibration frequency is selectable between 3,000 or 6,000 vibrations/minute at 50 Hz and 3,600 or 7,200 vibrations/minute at 60 Hz. The feed rate is continuously regulated via the output voltage. Mains voltage fluctuations are reliably compensated.

The maximum permissible current consumption (0.1–6 A) is programmable and electronically monitored. The vibrator’s soft start is adjustable (0.1–2.5 s), while shutdown is instantaneous. Optional cyclic operation allows separate setting of pulse and pause durations for vibratory or motor-driven hoppers.

The SE702 can be connected to other SE6XX/7XX controllers or integrated into a PLC architecture via the INTERFACE connections.

Digital operation with LC display
Menu-driven, backlit, code-protected

Memory for 10 feeding systems
Individual parameter sets can be stored

Selectable vibration frequency
3,000/6,000 (50 Hz)
3,600/7,200 vibrations/min (60 Hz)

Programmable current limiting (0.1–6 A)
Electronic monitoring

Stepless power control
With mains voltage compensation

Vibrator soft start (0.1–2.5 s)
Gentle start, immediate shutdown

Optional cyclic operation
Pulse duration 0.5–2.5 s
Pause duration 0.5–10 s

INTERFACE interface
PLC connection and cascading

Selectable vibrator or motor operation

Robust industrial design
EMC compliant, protection class IP20/IP40

Mains voltage according to rating plate

230 V, ±10%, 50/60 Hz

Output current mains voltage (230V OUT)

Max. 10 A, non-fused

Fuse

5 × 20 mm, 6.3 A very fast-acting (FF)

Operating mode (FUNCTION)

Vibrator control (VIBRATOR CONTROL)
Motor controller (MOTOR CONTROL)

Output current (OUTPUT CURRENT)

0.1…6 A, electronic current limiting

Vibrator frequency (VIBRATOR FREQUENCY)

3,000 or 6,000 vibrations/minute at 50 Hz
3,600 or 7,200 vibrations/minute at 60 Hz

Vibrator output voltage (VIBR. AMPL.)

0…220 V (230 V)

Motor output voltage

Mains voltage -5 V, non-adjustable

Vibrator soft start

0.1…2.5 s adjustable, 0.1 s fixed for pulse operation

Motor soft start

0.1 s fixed

Lock / enable input (LOCK)

PNP, 24 V, 10 mA

Cyclic operation pulse duration

0.5…2.5 s, 0.1 s steps

Cyclic operation pause duration

0.5…10 s, 0.5 s steps

Ambient temperature

0…+40° C during operation, -25…+70° C during transport

Protection class

IP20 or IP40, see safety information

Dimensions

143 × 223 × 72 mm